SunSynk 50KW Inverter - Three Phase
SUNSYNK-50K-SG01HP3-EU-BM4 THREE-PHASE
HYBRID INVERTER
Battery Input Data
Battery Type: Lithium-ion
Battery Voltage: 160~700V
Max. Charging Current: 50+50A
Max. Discharging Current: 50+50A
Max. Charging/Discharging Power: 55 000W
Charging Strategy for Li-Ion Battery: Self-Adaptation to BMS
Number of Battery Input: 2
PV String Input Data
Max. PV Input Power: 65 000W
Max. PV Input Voltage: 1000V
Start-up Voltage: 180V
MPPT Range: 150~850V
Full Load MPPT Voltage Range: 450-850V
Rated PV Input Voltage: 600V
Max. Input Short Circuit Current: 55+55+55+55A
Max. Operating PV Input Current: 36+36+36+36A
No. of MPPT/No. of String per MPPT: 4/2+2+2+2
Max. Inverter Backfeed Current To the Array: 0
AC Output Data
Rated AC Input/Output Active Power: 50 000W
Max. AC Input/Output Apparent Power: 55 000W
Peak Power (off-grid): 1.5 times rated power, 10sec
Rated AC Input/Output Current: 75.8/72.5A
Max. AC Input/Output Current: 83.4/79.8A
Max. Continuous AC Passthrough (grid to load): 200A
Max Three Phase Unblanaced Output Current: 83.4A
Rated Input/Output Voltage Range: 220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form: 3L+N+PE
Rated Input/Output Grid Friquency: 50Hz/45-55Hz, 60Hz/55-65Hz
Power Factor Adjustment Range: 0.8 leading to 0.8lagging
Total Current Harmonic Distortion THDi: <3% (of nominal power)
DC Injection Current: <0.5% ln
Efficiency
Max. Efficiency: 97.60%
Euro Efficiency: 97.00%
MPPT Efficiency: >99.00%
Communication
Communication Interface: RS485/RS232/CAN
Monitor Mode: GPRS/WIFI/Bluetooth/4G/LAN(optional)
Protection
Integrated: DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage, Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance, Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level: TYPE II (DC), TYPE II (AC)
Certifications and Standards
Grid Connection Standard: EN 50549-1, AS-NZS 4777.2, NRS 097-2-1; Additional connections available upon request
EMC/Safety Standards: IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data
Operating Temperature Range: -40 to +60ºC, >45ºC Derating
Permissible Altitude Humidity: 0~100%
Permissible Altitude: 2000m
Noise: <65 dB
Ingress Protection (IP): IP65
Inverter Topolgy: Non-Isolated
Over Voltage Category: OVC II (DC), OVC III (AC)
Size: 527*894*294mm
Weight: 80kg
Warranty: 1 5/10 years (with battery)
Type of Cooling: Intelligent Cooling
NOTE:
Safe Transport and Handling of Inverter:
When transporting the equipment, use its original packaging and keep it as a complete unit. Store the
product in a dry environment, avoiding direct sunlight, and maintain a temperature range between
-40°C and 60°C. Since the equipment can be quite heavy, always consider its total weight when mov-
ing, transporting, or installing it, ensuring that the installation site has adequate load-bearing capacity.
Transporting and installing the inverter should be carried out solely by qualified personnel.